Local Area Network Installation

Above is a diagram of the connection of the K2 to the local area network. The terminal server is connected to the RS-232 output of the K2. The terminal server is connected with a Cat V ethernet cable to the local area network 10/100 base t port. The commands needed and command options are provided below. Commands followed by [local] are options which must be provided by end user.

Lantronix MSS-100
Terminal Server

Local_1>set priv

Password>system

Local_1>> change ipaddress [local]

Local_1>> change gateway [local]

Local_1>> change subnet mask 255.255.255.0

Local_1>> change privpass [local]

Local_1>> change name "[local]" (station id recommended)

Local_1>> change autobaud disabled

Local_1>> change bootp disabled

Local_1>> change dhcp disabled

 

 

Local_1>> change domain [local] (optional)

Local_1>> change dsrlogout enabled

Local_1>> change flow control ctsrts

Local_1>> change inactive logout enabled

Local_1>> change inactive timer 10

Local_1>> change netware disabled

Local_1>> change access remote

Local_1>> change rarp disabled

Local_1>> change speed 19200

Return to Building Installation.

 





University of Utah Seismograph Stations  «»   135 South 1460 East, Room 705 WBB
Salt Lake City, Utah 84112-0111  «»   Phone 801-581-6274  «»  Fax 801-585-5585